Current Output
|
|
4 to 20mA OUTPUT RANGE
|
0 to 100μm pk-pk
0 to 125μm pk-pk
0 to 200μm pk-pk
0 to 250μm pk-pk
0 to 400μm pk-pk
|
4 to 20mA OUTPUT CONVERSION ACCURACY
|
±1.5 % of Full Scale Range (From test signal input pin to current output)
|
MAX. LOAD REGISTANCE
|
43.5 × (Vps-12) ( (Vps=Power supply voltage)
|
NOT-OK FUNCTION
|
Current output : 3.6mA or less.
Not-OK condition : Open or short of sensor,
Outside of linear range.
Delay time to resume ; 2 to 3 seconds after
Not-OK condition is removed.
|
GAP Output (Wave form output)
|
|
CALIBRATION MATERIAL
|
JIS SCM440 FLAT (AISI 4140 equivalent )
|
LINEAR RANGE
|
1.4mm (Gap : 0.3 to 1.7mm)
|
SCALE FACTOR
|
7.87mV/μm
|
SCALE FACTOR ERROR
|
7.87mV/μm±6.5% typ.
(including interchangeability errors)
Step : 200μm, Target : 30 mm dia.
|
OUTPUT IMPEDANCE
|
10k (It is calibrated load impedance at 10M)
|
System
|
|
FREQUENCY RESPONSE
|
5Hz to 6,000Hz (+0dB, -3dB) at 900μm Gap
|
TEMPERATURE RANGE OF TRANSMITTER
|
Operating : 0 to 70°C(32 to 158°F)
Storage : -34 to +100°C(-29 to +212°F)
|
TEMPERATURE RANGE OF SENSOR AND EXTENSION CABLE
|
Operating : -34 to +177°C (-29 to +350°F) (Connector : Max. 125°C (257°F))
Storage : -34 to +177°C (-29 to +350°F) (Connector : Max. 125°C (257°F))
|
RANGE OF TEMPERATURE AT EXPLOSION PROOF CONSTRUCTION
|
CSA,ATEX,KTL,TR-CU : 0 to +70C (Sensor, Ext. Cable & Transmitter)
|
RELATIVE HUMIDITY
|
95%RH (non condensing)
|
POWER SUPPLY VOLTAGE
|
12 to 35VDC
|
SENSOR TIP DIAMETER
|
Approx. 5.5mm (0.217 inch) dia.
|
CABLE DIAMETER
|
Approx. 2.7mm (0.106 inch) dia.
|
CONNECTOR DIAMETER
|
Approx. 7.1mm (0.280 inch) dia.
|
SYSTEM CABLE LENGTH
|
5m or 7m or 9m
|
TRANSMITTER SIZE
|
(L) 100mm × (W) 74 mm × (H) 50 mm (3.94 in) (2.91 in) (1.97 in) Mass : Approx. 530g (1.2 lb)
|