Format
|
Standard sizes; 400, 470, 500, 630, 800, 915, 1000, 1067. 1200, 1300, 1450, 1470, 1500, 1500 x 2000 and 2000 x 2000 mm. These formats are available in open and closed versions. Larger and differently sized formats on request.
|
Standard sizes: 400, 470, 500, 630, 800, 915, 1000, 1067. 1200, 1300, 1450, 1470, 1500, 1500 x 2000 and 2000 x 2000 mm. These formats are available in open and closed versions. Larger and differently sized formats on request.
|
Sludge inlet
|
Standard inlets: central inlet, decentralized inlet, corner inlet
|
Standard inlets: central inlet, decentralized inlet, corner inlet
|
Pressure
|
Depending on the version, standard products are suitable for a maximum filtration pressure of 8 bar or 16 bar.
|
Depending on the version, standard products are suitable for a maximum filtration pressure of 7 bar and a maximum squeezing pressure of 16 bar.
|
Temperature
|
The maximum permissible filtration temperature depends, among other things, on the filtration pressure, the chemical composition of the slurry to be filtered, the cycle time and the choice of material.
|
The maximum permissible filtration temperature depends, among other things, on the filtration pressure, the squeezing pressure, the chemical composition of the sludge to be filtered and the choice of material. In addition, the membrane can be cooled or heated during the filtration cycle.
|
Materials
|
Chamber filter plates can be made of the following materials for specific applications:
●Polypropylene homopolymer 1 copolymer
●Polypropylene Homopolymer FDA1 Copolymer FDA
●Antistatic polypropylene
●PVDF
●Antistatic PVDF
Other materials on request
|
Membrane filter plates can be made of the following materials for specific applications:
●Polypropylene homopolymer/ copolymer
●Polypropylene Homopolymer FDA1 Copolymer FDA
●Antistatic polypropylene
●PVDF
Antistatic PVDF
●Thermoplastic elastomers (membrane)
●EPDM (membrane)
●NBR (membrane)
●FKM (membrane)
For membrane filter plates, combinations of different materials for membrane carriers and membranes are possible.
|
Features
|
+ lowest price
+ good cake discharge
+ automatic plate shifting possible
+ easy handling
+ highly possible filtration pressure
- Cake thickness can not be changed
- Max. cake thickness 50mm
- Splitting wash not appropriate
|
+ shortest filtration, washing and dewatering time
+ most effective washing results
+ splitting wash possible
+ lowest dewatering costs
+ highest DM-Content
+ best cake discharge
+ flexible cake thickness
+ lowest energy input
- restrictions at high temperatures
- heavier use of the filter cloth
- special safety measures required
|