Item
|
Description
|
Fluid
|
Liquid (Not corrosive for PFA and PTFE)
|
Operating conditions
|
Free from combustible gas or liquid causing fire/explosion under normal condition
|
Pressure inlet
|
Tube connection, various types of nut, male screw (φ1/4, φ3/8, φ1/2 inch)
|
Wetted parts material
|
Diaphragm: PFA
Others: PTFE (PFA)
|
Pressure range
|
0 to 0.3, 0.5 MPa
|
Allowable pressure
|
0.7 MPa
|
Fluid temperature
|
10 to 80℃
|
Operating temperature
|
10 to 60℃
|
Storage temperature
|
-10 to 65℃ (No freezing inside the sensor)
|
Operating humidity
|
25 to 80%RH (No condensation inside the sensor)
|
Power source
|
24V DC±10% (2 wire system)
12 to 24V DC (3 wire system)
|
Output
|
2 wire system: 4 to 20mA DC (Load resistance: 500Ω max. at 24V DC)
3 wire system: 1 to 5V DC (Load resistance:10kΩ min.)
|
Transmission system
|
2 wire system or 3 wire system
|
Accuracy
|
±1.0%F.S.
|
Temperature coefficient
|
±0.05%F.S./℃ (Zero)
±0.05%F.S./℃ (Span)
Compensation temperature: 10 to 60℃
|
Setting system
|
External adjustment at zero point
|
Enclosure
|
Splash-proof excluding cable end (IP54)
|
Chassis material
|
Polypropylene (PP), fluorocarbon polymers (PTFE, PFA)
|
Weight
|
Approx. 180g (With cable)
|
CE compliance
|
Applicable Standards: EN61326-1:2013; EN61326-2-3:2013
|